This document describes the hand terminal settings for E-WMS Production Receipts, in menu System, E-WMS, Scanners, Production receipt settings.
Once scanner settings are defined, these need to be assigned to each device in menu System, E-WMS, Scanners, Scanners. You can use one general settings profile for all devices, or you can set up specific profiles per individual device. Please also read document General notes on scanner settings.
After selecting menu System, E-WMS, Scanners, Production receipt settings you can create a new profile by pressing New, or edit an existing profile by using Open. You can only delete profiles which are not linked to devices.
Name Unique code referring to this settings profile (12 characters).
Description Description of this settings profile (60 characters). You can jump directly to a specific section of settings:
Section: General
Screen layout ASP and WMSclient only, available from 404. Please read this section for more information on 'screen layout'. Focus to ASP only. Determines to what field you will return after a receipt line has been scanned. You have following choices:
If you scan production receipts per pallet, and you need a pallet label which is printed after reading back and processing the receipt, then focus to 'production order' may be an efficient choice. After each receipt, that receipt line is automatically completed (without having to press STOP on the scanner) and will be read back by the WMS RF service, allowing for automatic processing and label printing.
Prefill item code ASP only, available from 406. This setting has following options:
S/B number generation ASP only, available from 404. When this setting is enabled, you can generate new serial/batch numbers and print barcode labels from the hand terminal. When enabled, the 'S/B' button is available on the scanner. When disabled, the 'S/B' button is not available on the scanner. For more details, please see document E-WMS - Serial/batch generation.
Note: S/B number generation cannot be used together with the lot number functionality.
Prefill: S/B For E-WMS ASP only, available from 406. This setting allows you to prefill the serial/batch number when receiving serial/batch items, either as generated by E-WMS - Serial/batch generation (from 406), or as planned in the production order (from 407). This setting has following options:
Auto. SKU label screen ASP and SKU Management only. This setting determines if the SKU label print screen should appear automatically when no labels have been printed yet for the current order and SKU item. When enabled, the SKU label print screen will appear automatically when labels are still required. When disabled, the label print screen will never show automatically, you will have to press the OPTIONS + SKU button on the hand terminal. Use external SKU nrs ASP and SKU Management, available since 405. When enabled, external SKU numbers are accepted, you are not printing SKU labels from the hand terminal. When disabled, you are generating SKU numbers and printing SKU labels from the hand terminal during the receipt. Show stock button ASP only. Determines whether the hand terminal user is allowed to view item stock on the hand terminal. Before release 406, this setting was named 'RF: browse stock'.
Section: Bar code
Scanning combination ASP and CAB. Please read this document for more details on 'scanning combination' and 'dividing character'.
Dividing character ASP and CAB. Please read this document for more details on 'scanning combination' and 'dividing character'.
Use EAN128 ASP and CAB. When enabled, EAN128 decoding will be started for any scanned value. Please disable this setting when you do not use EAN128 bar codes. You can find more information in: how to activate EAN128 barcode scanning in WMS ASP and in document WMS CAB.
Focus to next field ASP only. Please read this document for more information on this setting. This setting is available in this screen from release 409, in earlier releases this was a general scanner setting. Show barcode summary Available from product update 404 (ASP and for WMS client only). When enabled, a summary screen will show (in which you have to press Enter or OK) after a scan, when otherwise you would have moved to the next transaction screen immediately. This way you still have a confirmation of what you scanned, before the next scan screen is shown. Typically, this will be the case when you have disabled the setting 'Focus to next field' and scanning a SKU number, or an EAN128 or HIBC bar code. Please also see this document for more information on this setting.
Section: warehouse
Default value You can configure a default warehouse for production receipts, and use it in combination with the setting 'Display which value'. Display which value? This setting determines if and how the 'warehouse' field on the scanner will be prefilled. The setting offers following choices:
The choices 'Default value', 'Never' and 'Empty' are applied in ASP and CAB, 'Advice' and 'Advice + skip' are only available in ASP.
Section: Location
Default value You can define a default location for production receipts. Since you could use any warehouse for thee receipts, there is no validation of the entered location in this screen. To apply a default receipt location, the setting 'Location/Display which value' will have to be configured to 'Default value' or to 'Never'.
Display which value? Determines how to prefill the 'location' field in the receipts process, with following options:
Section: Quantity
Default quantity ASP and CAB. Prefills the quantity field on the hand terminal with this value, when the quantity is not prefilled from a scan like an EAN128 bar code. The default value is 1. Change this value to 0 if you want to avoid just pressing 'Enter' in the receipts process too quickly (and receiving quantity 1). Display which value ASP only, available since 406. Allows you to prefill the quantity field on the sc, with following values:
Minimum quantity ASP and CAB. This setting determines the minimum quantity allowed to enter on the hand terminal. This setting is intended to avoid errors on the hand terminal, like scanning the item code or an EAN128 bar code in the quantity field.
Maximum quantity ASP and CAB. This setting determines the maximum quantity allowed to enter on the hand terminal. This setting is intended to avoid errors on the hand terminal.
Section: date registration
These settings determine what serial/batch dates will be registered on the scanners. Please read this document for more information on serial/batch date registration.
Section: Lot number
In this section you can enable the lot number functionality for this WMS process. The lot number functionality can be enabled for serial and/or batch items for the following WMS processes:
and is supported for the following actions:
Lot number for batch items Enable this option if you want to use the lot number functionality for batch items for the production receipt process.
Lot number for serial items Enable this option if you want to use the lot number functionality for serial items for the production receipt process.
Section: Scanner - Activesync
These settings are only applied when using the E-WMS CAB client without RF, so when you have to connect to a PC (cradle) to communicate with an E-WMS Control Center.
Serial/batch This setting determines how to handle input of serial/batch numbers in general. When there is no item master data on the hand terminal, it can not be determined if an item is a serial/batch item or not. Using this setting, you can still configure if you want to enter serial/batch number for all receipts, using following choices:
Normal (default value): serial/batch number entry is disabled (you never receive serial/batch items)
Serial: assumes you are always receiving serial number items (entry of serial number per single unit, but can be left empty)
Batch: assumes you are always receiving batch items (entry of batch number for each receipt, but can be left empty)
Browse items This setting determines whether it is allowed to to browse in item master data on the scanner, thus able to select an item from the list, instead of scanning an item code. If no item master data was exported to the scanner, then this setting could be disabled.